Frequently Asked Question

Firmware release notes for sensor family: QGxxN2 CANopen (I-type)
Last Updated 5 months ago

Release date: 20231103

This document is valid for:

  • QG65N2 CANopen Inclinometer
  • QG76N2 CANopen Inclinometer
Known issue, scheduled for new releases Temporary workaround
The 2 bytes in object 1003h (predefined error register) containing 'manufacturer error data' are currently swapped. The emergency message itself is OK.

Ignore 1003h or ‘swap back’ after reading

Store parameters object 1010h subindex 02h, 03h, 04h not implemented according CiA standardUse object 1010h subindex 01h to store each parameter

Firmware version number Changes with respect to previous version Date of release
V2.1.0Functionality added to do fast zeroing in LAB4 production automation.July 21th 2023

V2.0.0Functionality added to allow freedom in mounting positions.

Updated objects for automated factory calibration in LAB4.

Various minor updates.


Feb 22nd 2023

V1.0.0

Subrange functionality added for 1-axis vertical sensor (object 3032h).

Selectable resolution functionality added (object 6000h)
February 22th 2022
V0.6.1CAN object dictionary optimizedOctober 19th 2021
V0.3.12Function modes 6+7 added
Disable function modes 4+5
May 25th 2021
V0.3.4Initial releaseDecember 1st 2020